Compressor Installation and Application Review
Page 10 of 14
BW2514 ©2006 Bendix Commercial Vehicle Systems LLC • All Rights Reserved • 3/22/06 • rev: 1.
Coolant Return
Return Port Location: _____________________________
Line size to: ____________________________________
Distance to: ____________________________________
Measured coolant flow rate
At engine idle: ______________________
At engine rated speed: _________________
Recommended Test Procedure:
Install a flow meter in series with the coolant supply or return line of the air
compressor. Note the flow rate through the compressor when the engine
thermostats are open at engine idle and rated speed.
Was measured flow rate greater than .6 gpm at idle and 1.9 gpm at rated speed?
YES
NO
Measured Coolant Pressure Drop - alternative measurement
(pressure drop between inlet fitting and return fitting)
At engine idle: ______________________
At engine rated speed: _________________
Recommended Test Procedure:
Install pressure gauges at the inlet and outlet fittings of the air compressor. Record
the pressures (or pressure difference) at idle and rated speed.
Was measured pressure drop greater than 1.0 psi at idle and greater than 4.4 psi at rated speed?
YES
NO