Technical Bulletin
Bulletin No.: PRO-03-03 Effective Date: 8/22/75 Cancels: N/A Page: 1 of 1
Subject: USE OF LQ-3 VALVE IN SINGLE CIRCUIT SYSTEMS
This is to advise you that the LQ-3 and LQ-3-A’s can be used in a single circuit system
to replace the LQ-2 Limiting and Quick Release Valve and the Two-Way Control Valve,
only if a relay valve is added to the front axle system.
If you will note on your SD-67 under General Operations, page 3, the delivery port of the
LQ-3 or LQ-3-A is to be connected to the relay valve portion of the front axle adaptive
braking modulator.
Again, we want to stress, “Do not substitute the LQ-3 or LQ-3-A for the LQ-2 Limiting
and Quick Release Valve and the Two-Way Control Valve unless you add a relay valve
.”